Search results for "2204 Biomedical Engineering"

showing 2 items of 2 documents

Molekulare Signalwege der aseptischen Endoprothesenlockerung (Molecular pathways in aseptic loosening of orthopaedic endoprosthesis)

2008

Operative joint replacement to treat disabling joint conditions secondary to degenerative and inflammatory arthritides has become one of the most efficacious and cost-effective procedures to relieve pain and restore joint function. However, prosthetic implants are not built to last forever and osteolysis and aseptic loosening has been associated with prosthetic arthroplasties since their introduction. The functional life of a synthetic joint is influenced by many factors including the material of the implant, operation procedures and the surgeon involved, as well as patient-related factors. Although promising developments have been achieved in this field, more than 10% of all implants still…

musculoskeletal diseasesmedicine.medical_specialtyOsteolysisSignal Pathwaysbusiness.industryJoint replacementmedicine.medical_treatment10051 Rheumatology Clinic and Institute of Physical MedicineBiomedical EngineeringAseptic loosening2204 Biomedical EngineeringImplant failure610 Medicine & healthmedicine.diseaseSurgeryProsthetic implantsMedicineSmall particlesImplantbusiness
researchProduct

Histological and histomorphometrical analysis of a silica matrix embedded nanocrystalline hydroxyapatite bone substitute using the subcutaneous impla…

2010

The clinical suitability of a bone substitute material is determined by the ability to induce a tissue reaction specific to its composition. The aim of this in vivo study was to analyze the tissue reaction to a silica matrix-embedded, nanocrystalline hydroxyapatite bone substitute. The subcutaneous implantation model in Wistar rats was chosen to assess the effect of silica degradation on the vascularization of the biomaterial and its biodegradation within a time period of 6 months. Already at day 10 after implantation, histomorphometrical analysis showed that the vascularization of the implantation bed reached its peak value compared to all other time points. Both vessel density and vascula…

Materials scienceBone substituteBiomedical Engineering2204 Biomedical EngineeringBioengineering610 Medicine & healthBiomaterialsSubcutaneous TissueIn vivoAbsorbable ImplantsMaterials TestingAnimalsRats WistarBone regeneration11077 Center for Applied Biotechnology and Molecular Medicine1502 Bioengineering2502 BiomaterialsBiomaterialSilicon DioxideNanocrystalline materialRatsDrug CombinationsDurapatiteGiant cellSilica matrixBone SubstitutesSubcutaneous implantationNanoparticlesFemaleBiomedical engineeringBiomedical materials (Bristol, England)
researchProduct